BT-472 Rev. B
Express Fill 700 & 1000
Instruction Manual
Do not attempt to use or maintain these units until you read and understand these instructions. Refer to the Taylor-
Wharton’s Safety First
booklet (TW-202) for handling cryogenic material. Do not permit untrained persons to use or
maintain this equipment. If you do not understand these instructions, contact your supplier for additional information.
Przeglądanie stron 0
1 2 3 4 5 6 ... 25 26

Podsumowanie treści

Strona 1 - Instruction Manual

BT-472 Rev. B Express Fill 700 & 1000 Instruction Manual Do not attempt to use or maintain these units until you read and understand these ins

Strona 2 - BT-472 Rev. B

BT-472 Rev. B 10 Pressure Building Circuit The pressure building circuit serves to build pressure after filling the vessel. The circuit is also u

Strona 3 - WARNING

BT-472 Rev. B 11 The switch should be set to close at pressure below 125 psi and open after a predetermined pressure rise. To check the setting,

Strona 4

BT-472 Rev. B 12 Economizer Circuit The economizer circuit reduces product loss due to normal evaporation of the liquid within the vessel. The ec

Strona 5

BT-472 Rev. B 13 Instrumentation Circuits The instrumentation consists of a pressure gauge and differential pressure gauge. The pressure gauge (P

Strona 6 - System Description

BT-472 Rev. B 14 INSTALLATION Dimensions and connection data for the Express Fill systems can be found on the General Arrangement Drawings in the

Strona 7 - Specifications

BT-472 Rev. B 15 . Figure 9: Typical fill box installation diagram. Recommended components for a typical fill box installatio

Strona 8 - PIPING CIRCUITS

BT-472 Rev. B 16 Warning: Lines must not be installed such that they are susceptible to damage. A crushed safety line, for example, could prevent

Strona 9 - Express Fill Circuit

BT-472 Rev. B 17 OPERATION These instructions are for operators experienced with cryogenic equipment. Before operating this product,

Strona 10 - Pressure Building Circuit

BT-472 Rev. B 18 Withdrawing Gas To withdraw gas from the Express Fill system, connect a suitable line regulator to the gas withdrawal connection

Strona 11 - Gas Withdrawal Circuit

BT-472 Rev. B 19 MAINTENANCE Routine inspections of the system are recommended. The need for maintenance usually becomes apparent

Strona 13 - Instrumentation Circuits

BT-472 Rev. B 20 Regulators The pressure building regulator may be adjusted without removal from the system. The following procedure describes th

Strona 14 - Receiving Inspection

BT-472 Rev. B 21 1. Leak test joints between the high pressure cylinder regulator and the dump valve. Joints must be leak free before proceeding

Strona 15

BT-472 Rev. B 22 2. Close the liquid valve and the pressure building valve. Leave the vent valve open for the duration of the test. 3. Allow th

Strona 16

BT-472 Rev. B 23 Trouble-Remedy Guide Trouble Possible Cause Remedy a. Safety valve leaking or frozen open. a. Thaw out valve or replace if

Strona 17 - Filling by Pump Transfer

BT-472 Rev. B 24 Replacement Parts Order replacement parts from Taylor-Wharton Customer Service at 1-800-898-2657. Refer to the piping circuits s

Strona 18 - Changing Gas Service

BT-472 Rev. B 25 APPENDIXES Appendix 1 – Express Fill 700/1000 General Arrangement

Strona 19 - Globe Valves

4075 Hamilton Blvd. Theodore, Alabama 36582 U.S.A. Telephone (251) 443-8680 Fax (251) 443-2250 In U.S. and Canada:

Strona 20 - Regulators

BT-472 Rev. B 3 WARNING The following safety precautions are for your protection. Before installing, operating, or maintaining this unit read and

Strona 21 - Checking Vacuum

BT-472 Rev. B 4 parts. Also, be sure all replacement parts are thoroughly "Cleaned for Oxygen Service" in accordance with Compressed Gas

Strona 22

BT-472 Rev. B 5 Ten percent carbon dioxide in air can be endured for only a few minutes; twelve to fifteen percent soon cause unconsciousness; t

Strona 23 - Trouble-Remedy Guide

BT-472 Rev. B 6 INTRODUCTION This manual provides information for the operation and maintenance of Taylor-Wharton's line of Express Fill 700

Strona 24

BT-472 Rev. B 7 Specifications Model EF-700 EF-1000 EF-1000HP EF-1000VHP Dimensions Footprint inches 38 x 40 38 x 4

Strona 25 - APPENDIXES

BT-472 Rev. B 8 PIPING CIRCUITS The following paragraphs describe the operation of the piping circuits of the system. The descriptions refer to t

Strona 26

BT-472 Rev. B 9 Fill and Vent Circuits The liquid valve (V-1) communicates with the bottom of the vessel. A stainless steel tag labeled “LIQUID”

Komentarze do niniejszej Instrukcji

Brak uwag